Reported conditions and results for one submitted 12 mm Concrete Canvas / cement blanket sample, preserved with scope limitations and a link to the source PDF.

Read this limitation first

Commissioned test record, not a general certificate

Commissioned testing record for the submitted sample only. The report states that its results are limited to the submitted sample and does not provide an overall conformity determination.

The record shows the submitted sample as a 12 mm Concrete Canvas / cement blanket. It lists no overall judgement criterion. The issuer's report says the submitted information and sample were provided by the entrusting company, and the test results are limited to that submitted sample and that testing occasion.

Record details

Report, sample and testing context

Report

Report number: 2025W12239FY
Verification code: B6OTRJ
Report date: 19 January 2026

Sample

Concrete Canvas / cement blanket submitted sample, specification type 12 mm

Testing organization

China Building Material Test & Certification Group Suzhou Co., Ltd.

How to use this resource

Review the listed conditions and sample scope when discussing a project. Do not treat it as a substitute for product-specific specification, sampling or acceptance documentation.

Reported results

Methods, conditions and results as recorded

Test itemReported methodReported conditionsReported result
ThicknessGB/T 13761.1-2022(20 ± 2) °C; relative humidity (65 ± 4)%12.33 mm
Mass per unit areaGB/T 13762-2009(20 ± 2) °C; relative humidity (65 ± 4)%15 kg/m²
Flexural strengthGB/T 7019-2024, clause 5.7(23 ± 2) °C; relative humidity (50 ± 5)%; square specimen; loading time 10–30 s9.8 MPa
Impact resistanceGB/T 7019-2024, clause 5.9(23 ± 2) °C; relative humidity (50 ± 5)%; drop-ball method; 110 cm impact heightNo cracks
Water impermeabilityGB/T 7019-2024, clause 5.4(23 ± 2) °C; relative humidity >50%; 20 mm water head; 24 h test durationNo moisture marks or water droplets

Download / view complete PDF

Technical interpretation boundary

What the report cannot establish on its own

The record does not establish results for all thicknesses, batches, material constructions or future production. It does not identify a 3D textile, a 3D spacer construction, a composite woven construction or a needle-punched construction. It should not be used to claim universal standards compliance, permanent waterproofing, a production-line capacity or a named field-project outcome.